5 ALARM MANAGEMENT
If a malfunction occurs, the following procedure is activated:
1. audible alarm (beep);
2. one of the following system LEDs come on:
3. if the problem concerns an error, the stove will switch off.
Pressing and holding the "cancel" button
WARNING CODE
E111
button
for a few moments.
If the error code is "E108 or E109", before resetting the alarm, manually reset the
again.
26
DESCRIPTION
Faulty control panel
Remote control signal communication error Control panel fault
Communication error
Failed ignition error
Outlet water temperature too high
Temperature probe malfunction
Temperature probe malfunction
Safety error
Thermal safety
Incorrect pressure or thermal cutout
Pressure error
Temperature probe malfunction
Flue gas temperature probe malfunction
Low pellet level
Scheduled maintenance warning (icons
Pressure sensor malfunction (icon Pressure sensor or board fault.
Clean stove
Failed ignition error
;
shows the error code on the display:
POSSIBLE CAUSES
Control panel fault
Connection cable between board and control panel
interrupted or detached.
error
No pellets
Faulty ignition system
Burn pot dirty
Problems with the heating system
Problems with the pump
Faulty return water temperature probe
Faulty buffer tank temperature probe
Door or loading hatch open
Problems with the heating system
Problems with the pump
Problems with overheating in the pellet hopper
Flue system dirty
Seals worn
Heating system malfunction
Circulation pump malfunction
Pellet tank overheating
Seal gaskets worn
Faulty outlet water temperature probe
Faulty air temperature probe
Pellets running out
dirty.
Pressure measuring tubes detached or blocked.
Combustion air intake blocked.
No pellets; Faulty ignition heater; Worn gaskets; Incorrect
burn pot position
Then the stove can be started
LED
Fig.5.1