The stove allows the possibility to change the type of fuel used (wood/pellet) while the stove is already operating.
9.4.1 Switching from wood to pellets
To s itc to a tomatic pellet operatio
seco ds
1. t e i
itio LE
2.
3. after cleaning, the stove switches to pellet operation and the ignition LED
If the changeover to pellet operation has already been set, press the
the ignition LED
9.4.2 Switching from pellets to wood
1. open the door
2. load some logs of wood in the burn pot, making sure not to obstruct the pellet feed tube
3. close the door again
and therefore more fuel will need to be loaded manually to continue combustion.
The display will show the
When loading wood, the door needs to stay open for at least 3 seconds, so that the stove can recognise the
operation.

9.5 SWITCHING OFF

9.5.1
Wait until the stove has completely cooled down before starting it again.
9.5.2 Switching off in pellet mode
To switch the stove off in pellet operating mode, hold the
off.
Wait until the stove has completely cooled down before starting it again.
The stove should only be switched of f following the procedure described above. Never switch the stove of f by
unplugging it from the power supply.

9.6 OPERATION WITH ROOM THERMOSTAT (PELLET OPERATION ONLY)

When the stove is controlled by an external thermostat (or timer thermostat) the installer must have set
The stove switches on again automatically , in pellet mode, when the temperature falls below the value set on
the external thermostat (circuit closed).
directly from the control panel.

9.7 OPERATION WITH ROOM PROBE ON THE STOVE

The stove can be switched on/off manually or in programmed mode.
The stove modulates output according to the room temperature read by the probe on the stove (that is, the stove
attempts to maintain the desired temperature while minimising fuel consumption).
If the user has enabled the "Eco-mode" function , the stove rather than modulating its output, switches
off when reaching the set temperature, and switches on again when the room temperature falls below
the delta set (see par.10.3).
The desired room temperature can be set in the temperature menu
cod. 004771980 - 09/2014 - Palazzetti - PN - Italy
USE AND & MAINTENANCE
e operati
ill start as i
symbol on the fuel menu.
o
ood f el simpl
old t e
comes on steady.
button again to disable this function (
button), the stove needs to be started
.
tto for a fe
51/144

Publicité

Table des Matières
loading

Table des Matières