1. Remove the conductors L1, L2 and, if necessary, N from the terminal blocks of the terminal
points AC-out (round opening). To release the conductors from the terminal points, open the
terminal points with a flat-blade screwdriver (blade width: 3.5 mm (0.14 in)). To open the
terminal points, insert the flat-blade screwdriver into the actuation shaft of the terminal block
(rectangular opening).
2. Also shorten the rest of the insulating hose to the necessary length. Make sure the insulating
hose can be guided over the jacket of the conductors after shortening.
3. Place the insulating hose over the AC
conductors. Place the insulating hose over the
jacket of the conductors.
4. Depending on the grid configuration, connect the conductors L1, L2 and, if applicable, N to
the terminal block for AC-out:
Connection of conductors of finely stranded wire
To connect conductors made of finely stranded wire, each terminal point must be opened.
• First insert the connector into the terminal point all the way to the lock (round opening).
Then insert a flat-blade screwdriver (blade: 3.5 mm (0.14 in)) as far as it can go into the
actuation shaft (rectangular opening). Hereby the lock opens and the conductor can be
placed into the terminal point as far as possible. After the connection has been made,
the flat-blade screwdriver must be pulled out of the actuation shaft.
• If a neutral conductor is present, place the
neutral conductor into the terminal point
(round opening) N as far as possible.
Installation Manual
AC-out
SPS
_
+
ANT.
DC OK
+
+V DAJ
100-240VAC
0.88A
50/60Hz
L
N
D-IN
SPS
RoofCommKit-P1-US-IA-xx-11
5 Connection
23