Electrial Connections - Thermador DWHD650WFM Instructions D'installation

Masquer les pouces Voir aussi pour DWHD650WFM:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Electrical Connection
!
WARNING
Avoid Electrical Shock Hazard!
Do not work on an energized circuit . Doing so
could result in serious injury or death . Only qualified
electricians should perform electrical work . Do not
attempt any work on the dishwasher electric supply
circuit until you are certain the circuit is de-energized .
To avoid possible injury or property damage, care
should be exercised when the dishwasher is installed
or removed to reduce the likelihood of damage to the
power cord .
Avoid Fire Hazard!
Make sure electrical work is properly installed and
checked by qualified electricians .
Make sure there are no loose electrical connections .
Make sure all electrical connections are properly made .
Loose and improperly installed electrical
connections can result in overheating!
Carefully review terminal block installation instructions .
To avoid risk of fire, observe the following precautions:
DO NOT remove, bypass or alter the terminal block .
Wall Socket Connections:
Only use the provided power cord for wall socket
connections .
DO NOT attach an extension cord or any type of
modified cord or adapter with this appliance .
DO NOT cut or splice the power cord .
DO NOT alter the power cord in any way .
Permanent Wire Connections (in addition to the
warnings above):
Only use the junction box power cord, sold as
Accessory kit #SMZPCJB1UC .
Carefully review the terminal block installation
instructions .
DO NOT remove, alter or bypass the terminal block .
ELECTRICAL SUPPLY
The customer has the responsibility of ensuring that the dish-
washer electrical installation is in compliance with all national
and local electrical codes and ordinances . The dishwasher is
designed for an electrical supply of 120V, 60 Hz, AC, connect-
ed to a dishwasher-dedicated, properly grounded electrical
circuit with a fuse or breaker rated for 15 amps . Electrical sup-
ply conductors shall be a minimum #14 AWG copper wire rat-
ed at 75°C (167°F) or higher .
DISHWASHER ELECTRICAL RATING
Volts Hertz
120
60
GROUNDING INSTRUCTIONS
The dishwasher must be properly grounded before operating .
This appliance must be connected to a grounded metal per-
manent wiring system or an equipment grounding conductor
must be run with the circuit conductors and connected to the
equipment grounding terminal or lead on the dishwasher .
Do NOT use extensions cords .
Make sure that the dishwasher is connected to a suitable
ground in compliance with all local codes or, in the absence of
a local code, with the NATIONAL ELECTRICAL CODE in the
United States or the CANADIAN ELECTRIC CODE C22 .1-lat-
est edition in Canada as well as any provincial/state or munici-
pal or local codes that apply .
Note: Installations requiring hard wiring and terminal
block - The accessory terminal block/junction box model,
SMZPCJB1UC, designed for permanent wire connection, is
not included but can be ordered through Customer Service
by calling 1-800-944-2904 . Follow the instructions included
with the kit .
Amperes
Watts
12
1,440
(max)
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dwhd770wfpDwhd770wfmDwhd770wpr

Table des Matières