4.4
Technical data
Model
Type
Output
(1)
min - max
Delivery
(1)
Fuel
Gas pressure at maximum delivery (2) -
Gas: G20/G25
Operation
Nozzles
Standard applications
Room temperature
Combustion air temperature
Electrical supply
Electric motors
Fan motor
Pump motor
Ignition transformer
Pump
Delivery (at 16.5 bar)
Pressure range
Fuel temperature
Electrical power consumption (Light oil)
Electrical power consumption (Gas)
Protection level
Noise level
Sound pressure
(3)
Sound power
Reference conditions: Ambient temperature 20°C - Gas temperature 15°C - Barometric pressure 1013 mbar - Altitude 0 m a.s.l.
(1)
Pressure at test point 5) (Fig. 5) with zero pressure in the combustion chamber and maximum burner output.
(2)
Noise emission tests carried out as specified in EN 15036-1 with measurement accuracy σ = ± 1.5 dB, in the manufacturer's combustion chamber
(3)
with burner operating on test boiler at maximum output.
4.5
Burner weight
The weight of the burner complete with its packaging is shown in
table.
Model
RLS 800/EV MX
Technical description of the burner
kW
kg/h
mbar
number
°C
°C max
rpm
V
kW
A
V
kW
A
V1 - V2
I1 - I2
kg/h
bar
°C max
kW max
kW max
dB (A)
kg
320
RLS 800/EV MX
1750/3500 - 8000
147/295 - 674
20 °C: 6 mm
LIGHT OIL, viscosity at
NATURAL GAS: G20 (methane
- GPL: G31 - PCI 26 kWh/Nm
50.6 / 75.4
- Intermittent (min. 1 stop in 24 hours)
-
Progressive two-stage or modulating by kit (see accessoires
Boilers: water, steam, diathermic oil
3N ~ 400 / 230V +/-10% 50 Hz
380 - 415 660 - 718
230 V - 1 x 5 kV
1 A - 20 mA
7
GB
1301 T2
2
/s (1.5 °E - 6 cSt)
) - G21 - G22 - G23 - G25
3
1
0 - 50
60
2900
21
40 - 23
230/400
1.5
6.4/3.7
560
6 - 30
140
26
24
IP 54
89.6
103.9
)
D9199EV
Fig. 1
20010950