2. How to use
3. Troubleshooting and service
Repairs must only be carried out by
authorised professionals.
If a fault in your appliance cannot be
rectified with the aid of this table,
please contact the service organisa
tion of your importer or the Central
Customer Service Department. Please
have the details of the typeplate at
hand.
CLAGE GmbH
AfterSales Service
Pirolweg 1 – 5
21337 Lüneburg
Germany
Phone: +49 4131 890140
Fax:
+49 4131 890141
Email: service@clage.de
Cleaning and maintenance
• Plastic surfaces and fittings should only be wiped with a damp cloth. Do not use
abrasive or chlorinebased cleaning agents or solvents.
• For a good water supply, the outlet fittings (special tap aerators and shower heads)
should be unscrewed and cleaned at regular intervals. Every three years, the electri
cal and plumbing components should be inspected by an authorised professional in
order to ensure proper functioning and operational safety at all times.
This instantaneous water heater was manufactured conscientiously and checked sever
al times before delivery. Should malfunctions nevertheless occur, it is usually only due
to a bagatelle. First attempt to switch the house fuses off and on again in order to reset
the electronics. Next, try to remedy the problem with reference to the following table.
In doing so, you will avoid unnecessary expense of customer service assistance.
Problem
Water stays cold, digital
display does not light up
Water stays cold, digital
display does light up
Display flashes error
message "Er"
Flow rate of hot water too
weak
Selected temperature is
not reached , decimal point
lights up
Selected temp. is not
reached , decimal point does
not light
Decimal point flashes
No response upon keypress
9
Cause
Solution
Master fuse tripped
Renew or activate fuse
Safety pressure cut
Contact customer service
out tripped
Safety thermal cut
Contact customer service
out tripped
Switch fuse off and on. If "Er"
Control system has
still flashes contact customer
switched off
service
Outlet fitting dirty
Clean shower head, jet
or calcified
regulator or sieves
Fine filter dirty or
Let clean fine filter by customer
calcified
service
Water flow rate too
Reduce water flow rate at the
high
tap
Cold water has been
Tap hot water only; set
added via the tap
temperature for use
Inlet temperature
exceeding nominal
Reduce inlet temperature
temperature
Hood is not fitted
Let refit the hood properly by
properly
customer service
CLAGE
EN