1.

GENERAL INSTRUCTIONS

Thank you for purchasing this multi-function digital earth tester.
This instrument complies with safety norm EN 61010-1 Ed. 2 (2001) applicable to electronic
measuring instruments. It allows operators to check that installations comply with IEC
61557.
For your safety and to get the most from your instrument, please:
Read these operating instructions carefully,
Follow the written user instructions
The contents of this manual may not be reproduced in any form without our consent.
1.1.

Precautions and safety measures

1.1.1. Before using the tester

This instrument is designed for use indoors, within a pollution level 2 environment, at an
altitude of less than 2000 m, at a temperature of between 0°C and 45°C, with 80 %
relative humidity up to 31°C.
It can be used for testing category III installations, with voltages that do not exceed
300 V in relation to the earth.
Definition of installation categories :
CAT IV:
Measurement category IV corresponds to measurements taken at the source of
low-voltage installations.
Example: power feeders
CAT III:
Measurement category III corresponds to measurements on building
installations.
Example: industrial machinery or instrument power supplies
CAT II:
Measurement category II corresponds to measurements taken on circuits
directly connected to low-voltage installations.
Example: household appliance and portable tool power supplies
CAT I:
Measurement category I corresponds to measurements taken on circuits not
directly connected to the network.
Example: protected electronic circuits
The leads and connection accessories used must be designed for a specific voltage and
an over-voltage category equivalent at least to that of the circuits on which the
measurements are carried out.
The safety of any system incorporating this instrument is the responsibility of the system
assembler.
Check the condition of the instrument, leads and connection accessories before
use. Do not use the device if the battery compartment is missing or damaged.

1.1.2. Using the tester

Never use the instrument outside the specifications and protection levels described in
this manual.
Automatic shutdown: the device will shut down automatically if the instrument is not used
for 10 minutes (see paragraph 2.1.1, p. 29).
Turn the switch to "O" to avoid discharging the accumulator pack or the batteries.