Setting the detection range

The upper beam is fixed: it always remains parallel to the ground. The lower beam can be adjusted
(see below). Given that the beams (lower and upper) must be broken simultaneously to trigger an alarm,
the detector range is limited to the range of the lower beam.
Détection !
Detection!
Portée de détection
Detection range
The lower and upper beams are
broken.
1
Set the range by gently sliding the lens in its
housing.
(The lower left and right-hand zones can be set
independently).
Ensure that the lens remains parallel with the holder.
DO NOT TWIST IT.
Position/Range look-up table
(Installation height = for example 1 metre)
Maximum range per side
Position
Standard
A
12 m
B
8 m
C
5 m
D
2 m
* The maximum detection range may vary according to the atmospheric conditions.
2
Replace the lens holder in the front cover,
aligning the three marks (X, Y and Z) on each side
of the lens holder with the three notches (X', Y' and
Z') on the front cover, ensuring that the 6 clips are
correctly inserted.
68
Pas de détection !
No detection!
Portée de détection
Detection range
Only the lower beam is broken.
Variations *
10 to 15 m
6 to 10 m
4 to 8 m
1.5 to 3 m
Pas de détection !
No detection!
Portée de détection
Only the upper beam is broken.
OUI
YES
Copyright © 2015 Somfy SAS. All rights reserved.
Detection range
NON !
NO!
X'
X
Y'
Y
Z'
Z