wall distance minimum
0,4 m
Diagramm showing installation of the TTR 55 S dehumidifier
• The unit output depends solely on the room
conditions, room temperature, relative humi-
dity and observance of the installation instruc-
tions.
Electrical connection
• The units operate on
230V AC/50 Hz.
• Electrical connection takes
place using the fitted power
cord with safety plug.
NOTE
For installation of the units in damp areas such
as utility rooms, shower rooms or similar, the
units must be protected with a residual-cur-
rent-operated circuit-breaker complying with
the rquirements.
• Cables must only be extended depending on
the cable length, unit rating and taking local
use into account.
ATTENTION
All extension cables must only be used un-
coiled.
The unit must not be disconected from the
supply before the after-running time of 2 mi-
nutes has elapsed.
maintain distance to radiators or other heat
sources

Safety information

The units were subjected to extensive material,
functional and quality inspections and test prior
to delivery.
However, the units may constitute a hazard if
used by untrained personnel, improperly or not
for the intended purpose.
The following information must be observed:
• The units must not be installed and operated in
hazardous areas.
• The units must not be installed and operated in
oil, sulphur, chlorine or salt containing atmos-
pheres.
• The units must be installed upright and stab-
le.
• The units must not be exposed to direct water
jets.
• The air openings must always be kept free.
• The air inlet grilles must always be kept free of
dirt and loose objects.
• The units must not be covered during operati-
on.
• Nerver insert foreign objects into the units.
• The units must not be transported during ope-
ration.
Operating manual – Dehumidifier TTR 55 S
• The units must only be transported upright.
• The condensate containers must be emptied
prior to each change of location.

Commissioning

Prior to each commissioning or as required, the
air inlet and outlet grilles must be checked for
clogging.
NOTE
Clogged grilles and filters must be cleaned or
replaced immediatly.
Important information prior to commissio-
ning:
• All electrical extension cables must have a
sufficient crosssection and only be used fully
uncoiled.
• Do not pull the power cord.
• After switching on, the units operate fully au-
tomatically until switched off controlled by the
timer or float switch of the full condensate
container.
• T he condensate container must be fitted cor-
rectly.
The unit will not function if the condensate
container is not fitted correctly!
• For safety reason, the units are fitted with a tilt
switch which prevents operation of a unit that
has toppled over or is lying horizontally.
The unit can only be restarted when it is
placed upright!
• I n an unsupervised continuous mode with ex-
ternal condensate connection, the produced
condensate is continuously drained via a hose
connection on the condensate container.
Control panel
The control panel contains control buttons and
indicator lights.
6
4
5
3
2
1
B - 2
A - 2