Information About The Device - Trotec MD 02-16 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26

Information about the device

Description of the device
This device uses the principle of condensation to
automatically dehumidify rooms.
The fan sucks damp room air through the air inlet (2),
the air filter (3), the evaporator and to the condenser
located behind it. The air is cooled at the cold
evaporator until it is below the dew point. Water
vapour contained in the room air precipitates on the
evaporator fins as either condensation or frost. The
dehumidified, cooled air is rewarmed at the
condenser and blown out at a temperature of
approx. 5 °C above room temperature. The drier air
which is prepared in this way mixes with the air in the
room. The humidity in the room where the device is
positioned is reduced as air constantly circulates
through the device. Depending on the air temperature
and the relative humidity, the condensed water either
drops continuously or only during the defrost phase
into the condensation tray and through the integrated
drain nozzle into the condensation tank (4) below. The
condensation tank (4) is fitted with a float to measure
the fill level.
The device has a control panel (1) for operating and
controlling the functions. Once the maximum fill level
of the condensation tank (4) is reached, the
condensation tank indicator light ("TANK FULL") on
the control panel (1) is lit. The device switches off. The
condensation tank indicator light only goes out again
once the emptied condensation tank (4) is reinserted.
The condensed water can be diverted by attaching a
hose at the condensation plug (6).
EN
Device depiction
No.
Operating element
1
control panel
2
air inlet
3
filter slot and air filter
4
condensation tank
5
air outlet
6
cover for attaching a hose to the condensation plug
Operating Manual – Dehumidifier MD 02-16