Trotec TTR 55 S Mode D'emploi page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1.
ON / OFF
The unit is switched on and off with this but-
ton.
Note the switch off delay of about 2 minu-
tes.
2.
MODE
This button is used for selecting the 3 modes
„POWERFUL", „SILENT" and „NORMAL".
3.
TIMER
This button is used to activate the switch off
timer for 2, 4 or 8 hours.
4.
AUTO SWING
This button is used to activate the automatic
swing mode of the air directing flap.
5.
IONIC
This button is used to switch on the ioniser for
enriching the room air with negatively charged
ions.
5.
„FULL TANK" indicator light
The indicator light shows when the condensate
container is full and requires emptying. When
the unit is switched off via the float switch, the
unit generates 5 audible signals.
Unit commission
1. C onnect the units to a properly
fused power socket.
2. Press the ON/OFF button on the
control panel.
NOTE
As long as the unit is not disconnected from
the power supply, the last selected mode
(MODE, IONIC and AUTO SWING) is activ when
the unit is switched on.
3. The air directing flap at the top of the unit
opens fully. The unit is the „NORMAL" mode
and the ioniser and timer are not activated.
4. S elect the required mode with the „MODE"
button.
NORMAL
This is the comfort mode. The unit regulates ac-
cording to time (12 hours) or on reaching the pre-
set humidity, the dehumidification capacity and
fan setting.
relative humidity above 55%
- max. dehumidification capacity
- moderate fan setting
relative humidity below 45 - 55%
- min. fan setting relative humidity below
45%
- dehumidification off
- min. fan setting
B - 3
A - 1
Electronic program sequence
Mode
Power consumption
2. Setting / 560W
NORMAL
1. Setting / 340W
1. Setting / 340W
SILENT
2. Setting / 560W
POWERFUL
After 12 hours continuous operation at max. power aetting, the contral automatically selects the min.
power setting.
If the relativ humidity subsequently falls below 45 %, the dehumification function is switched off.
The fan continues to run at minimum speed for moisture measurement. If the relative humidity
subsequently rises above a value of 45 % again, the minimum dehumidification setting is activated.
Return to the maximum power setting can only take place via the ON/OFF button manually.
SILENT
This is the most silent mode. Optimal for night
operation.
relative humidity above 55%
- min. dehumidification capacity
- min. fan setting
relative humidity below 45
- min. fan setting relative humidity below
45%
- dehumidification off
- min. fan setting
POWERFUL
relative humidity 45 - 55%
- max. dehumidification capacity
- min. fan setting
relative humidity below 45% , so that the air
we inhale seems „pure"
- dehumidification off
- max. fan setting
ATTENTION
After 12 hours operation at maximum power,
the control automatically selects the min. po-
wer setting.
„AUTO SWING" button
This button is used to activate the oscillating fuc-
tion of the air directing flap.
Pressing the button again stops the flap at the
respective position. The most favourable air flow
position can be selected in this way. The swing
function serves to improve the air distribution wi-
thin the room.
Operating manual – Dehumidifier TTR 55 S
Fan setting
medium
min.
min.
min.
min.
max.
max.
The following information must also be ob-
served:
• Free air flow must be ensured.
This ensures optimal unit operation!
• i t must be ensured that sensitive items, e.g.
indoor plants are not placed directly in the air
flow.
IONISER
The unit has an ioniser generator to produce ne-
gative ions.
A high concentration of negative ions occurs, e.g.
in mountainous regions, at waterfalls and in fo-
rests the air we inhale is „pure". Only a small ion
concentration is present in rooms.
Here, the ion generator is able to enrich the oxy-
gen molecule ions in the circulated air and provi-
de a pleasant atmosphere.
Also, suspended and dust particles in the air are
bound so that natural air purification can take
place.
As a result of ionisation, the dust is able to acu-
mulate on smooth surfaces and removed manu-
ally.
This function is active in all modes after selec-
tion.
NOTE
The housing and filter cleaning intervals re-
duce when using the ioniser.
TIMER
This button is used to program a decremental
switch off timer. The timer can be set 2, 4 or 8
hours by pressing the button repeatedly. Pressing
the button again switches off the timer.
Empty condensate container
The installed condensate container must be emp-
tied from time to time.
When the condensate container is full, dehumi-
dification is interrupted with the generation of
an audible signal.The „Tank full" indicator light
Realtive humidity
above 55%
45 - 55%
below 45%
above 45%
below 45%
45 - 55%
below 45%

Publicité

Table des Matières
loading

Table des Matières