Operating Elements; Preparation; Technical Data - Soehnle SHAPE SENSE CONTROL 200 Mode D'emploi

Masquer les pouces Voir aussi pour SHAPE SENSE CONTROL 200:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
A. Operating elements
EN
1. Minus ( )
2. Confirm ( )
3. Plus ( )
Sensor Touch: Touch
keys only slightly!
B. Preparation
1. Remove battery strip.
Note: Immediately (as long as „0.0" is still
being displayed) place the body analysis scale
on a level surface and wait until the scale
powers down automatically.
Then begin data input. Otherwise, it might be
possible that the weight of the scale would
erroneously be added to the initial weighting
process.
The same might occur during regular operati-
on if the scale is held in the hand prior to the
weighting process.
2. For all measurements, place scale level on a
hard surface (not carpet).
3. Cleaning and Care: clean only using slightly
damp cloth. Do not use solvents or abrasives.
Never submerge scale in water.
4. A country-specific option to switch from kg/cm
to lb/in or st/in is possible by pushing the key
on the bottom of the scale to switch units.
Attention! Slipping hazard
in case of wet surface.
C. Data input
1. Push
key.
2. Use
/
keys to select memory slot and con-
firm ( ).
3. Then use
/ keys enter body height.
Use
to confirm.
4. In the next step enter the age and confirm.
5. Finally select sex and confirm.
6. Now immediately place the body analysis
scale on the floor, wait until the screen dis-
plays „0.0" and then step on the scale with
bare feet.
4
63858-BA-PWD-Modell-R-13199-A-Content-10-08-2016.indd 4
The initial measurement is indispensable and
serves to store the data for later automatic
recognition of persons. If no person steps on
the scale, data input must be repeated.
The first body analysis is performed after a
person steps on the scale.
This scale is equipped with a Time-Out mode.
It will automatically switch off after approx.
40 seconds if no keys are pressed.
Data must be entered again after battery
change.
D. Body analysis
1. Place scale on hard, level surface and wait
until the scale switches off automatically.
2. Step barefoot onto scale. Please stand still.
3. The body weight will be displayed.
The scale determines the body values (body
fat, body water, muscle mass, kcal).
Note: Body values are calculated based on the
determined weight and the personal data.
The scale shuts off auto matically.
E. Notifications
1. Replace batteries
2. Overload: max. 180 kg
3. The measured value is higher (H) or lower (L)
than the limit.
10 - 60 % 5 -90 % 5 -90 %
4 - 60 % 5 -90 % 5 -90 %
F. Technical data
Max. 180 kg/100 g
Max. 396 lb/0.2 lb
Max. 28 st/0.2 lb
Batteriy requirement: 1 x 3V CR 2430
12.08.2016 13:03:58

Publicité

Table des Matières
loading

Table des Matières