Set the channel 1 switch C6 (13) on programme position then proceed as above.
. Replace switch C6 in normal position.
Setting the time of the Microquartz
- Set the keyboard switch to ON.
- Stop the clock by pressing the Stop/start key : the red LED lights up.
- Set the clock to the exact day and time using the + 1 h, - 1 h, min keys.
- On the time signal press the Start/Stop key : the red LED switches OFF, the second start
counting.
- Set the keyboard switch to OFF
The slave clocks will synchronize themselves automatically either catching up or in stand-by
if they are ahead less than 1 h. catching up cycle is 24 h.
Note : It is possible to check the slave clocks time at any time :
- for min 24 V, 1/2 min 24 V and SR2 / SR3 by pressing the enter key,
- for D1 D2 and Telesect by setting the channel 6 (13) switch to program and pressing the
enter key.
SEASONAL TIME CHANGE
Seasonal time changes can be performed instantly or preset up to 1 week in advance.
. Instant time change :
- Set the keypad switch to ON.
- Press briefly the + 1 h for summer time and -1 h for winter time.
- Set the keypad switch to OFF.
. Preset time change :
- Set the keypad switch to ON.
- Press the + 1 h (summer time) or -1 h (winter time) key and hold it for 5 sec until
the display shows :
- Enter the day and time of the changeover.
EG. Sunday 03h00 : the display blinks.
. Press ENTER key.
The display shows the tiem of the day again.
- Set the keypad switch to OFF.
To check time of the changeover proceed as above : the preset day and time will be
displayed.