Code on
display
D1-D2 220 V 3 wires +
PO
04
minute 24 V
D1-D2 220 V 3 wires +
PO
05
1/2 minute 24 V
Telesect impulses 220 V 4 wires +
PO
06
minute 24 V
Télésect impulses 220 V 4 wires +
PO
07
½ minute 24 V
Synchronous wired 3wired
PO
08
Example : 24 V min. impulse + D1 D2 3-wire = code P0....04
- Press 4 times the second key to obtain.
- Enter. The display shows :
P1 - Selection of the impulse duration
Impulse duration is adjustable to the minute, 1/2 minute, SR2 output (clock line terminal 18)
from 1 sec to 1.8 sec.
The clock is delivered with 1.3 sec duration.
- Press the second key to disply the required duration.
EG. Impulse duration 1.8 seconds.
- Enter. The display shows :
P2 - Selection of operating mode
For the Microquartz 6 : always enter.
For the Microquartz 6 R : select the operating mode
. Stand alone enter.
. Slave operation controlled by another master clock.
Type of impulses
. On minute
. On 1/2 minute impulse.
Output terminal