Assembling The Head - Valve Units - Pratissoli LK Serie Manuel De Réparation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 70
Take out the valve guide spacer using an 8 mm hex wrench
(pos. , Fig. 111).
Extract the suction valve unit with an extractor hammer to be
applied on the M10 hole of the valve guide (pos. , Fig. 112).
If removing the suction valve unit proves to be
particularly difficult (for example because of
incrustations due to prolonged inactivity of the
pump), use the extractor tool (code 27516200
(for LK36-LK40-LK45) or code 27516300 (for
LK50-LK55-LK60)(pos. , Fig. 113) as indicated.
Remove the suction and outlet valve units, unscrewing an M10
screw in such a way to press on the inner guide and remove
the valve guide from the valve housing (pos. , Fig. 114).
Fig. 111
2.2.2
Assembling the head – valve units
Pay particular attention to the conditions of the
various components and replace if necessary.
At every valve inspection, replace all O-rings
both in the valve unit and in the valve plugs.
Before repositioning the valve units, thoroughly
clean and dry the relative housings on the head
indicated by the arrows (pos. , Fig. 115).
Fig. 112
Proceed with reassembly following the reverse order indicated
in par. 2.2.1.
Fig. 113
57
Fig. 114
Fig. 115

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Lk36Lk40Lk45Lk50Lk55Lk60

Table des Matières