DSX ELECTRONIC MPS ®
3. Technical specifications
Model
Energy efficiency class
Rated capacity / rated current
EN
Chosen capacity / current
Electrical connection
Min. required cable size
Hot water (l/min)
2)
max. at ∆t = 28 K
max. at ∆t = 38 K
Rated volume
Rated pressure
Connecting type
Heating system
@ 15 °C:
Required spec. water resistance Spec.
electrical conductivity
Inlet temperature
Flow rate to switch on – max. flow rate
Pressure loss
Temperature range
Water connection
Weight (when filled with water)
VDE class of protection
Noise level test certificate
Type of protection / safety
*) The declaration complies with the EU regulation No 812/2013
1) Maximum applicable cable size is 10 mm
2) Mixed water
3) Electronically controlled depending on the desired temperature and cold water temperature
Model
Operating voltage
Type of battery
Type of protection
Transmission range
Transmission power
Transmission and
receiving frequency range
Radiation
Approvals
1) Do not use rechargeable batteries.
18 kW (26 A)
1)
4.0 mm
9.2
6.8
2
DSX SERVOTRONIC MPS ®
18 kW..27 kW (26 A..39 A)
21 kW (30 A)
3~ / PE 380..415 V AC
2
4.0 mm
2
10.7
7.9
1.0 MPa (10 bar)
pressure-resistant / pressureless
Bare wire heating system IES ®
≥ 1,100 Ωcm
≤ 90 mS/m
≤ 70 °C
2.5 l/min – automatic
0.2 bar at 2.5 l/min
20 – 60 °C
PA-IX 6822/I
Remote control FX
2 × AAA Alkaline
IP 20
10 metres incl. barrier
< 10 mW
868.0 – 868.6 MHz
undirected
Europe EN 300 220 / CE
18
A *
)
24 kW (35 A)
6.0 mm
2
12.3
9.0
0.4 l
3)
1.3 bar at 9.0 l/min
G ½"
4.2 kg
I
IP25
3 V
1)
27 kW (39 A)
3~ / PE 400 V AC
6,0 mm
2
13.8
10.2