Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Options

Control module Millenium option
With four-line plain text display for status, warning and fault
messages.
The device comes equipped with a freely programmable logic
module offering the following functions:
Basic functions
• Function monitoring of fans, heating system and rotor drive
• All warnings or faults are displayed in plain text (for full
particulars see chapter Errors and faults)
• Information regarding important basic settings and
operating conditions (target and actual values) is displayed
in plain text
• The energy management is optimized by a constant
monitoring and continuous control of the regeneration
temperatures RHZ and RAL
Further optional functions (factory configuration required)
• continuous control of the outlet humidity level in partial-
load operation (only in combination with a moisture
measuring device and humidity control kit)
• continuous control of the outlet temperature of the dry air
(only in combination with a temperature probe,
temperature control kit, additional electrical heating or air/
water heat exchanger with control valve)
• 2-stage air volume switching for reducing the outlet
humidity level through a lower volumetric flow (only in
combination with Flowmatic S)
• electric reheater for heating the dry air additionally
The Millenium control module is located behind the left section
of the front cover inside the electrical control box. To be able to
read the control module's display, first open the front cover of
the device (see instructions):
23
Operation
The PLC will be activated as soon as the main switch is
switched on. The start screen (return) can be opened at any
time by pressing the [ESC] button.
Returning to the start screen is also possible via the [B] button:
You can browse the screens using the buttons A and B. The
following screens will be displayed:
• Welcome and version number.
• Indication of target and actual values for RHZ and
RAL temperatures (humid air outlet).
• Indication of target and actual values for differential
pressure, humidity level, dew point. The display may vary
depending on the option installed.
• Indication of basic settings (distributed over several screen
pages).
• Display of basic settings
• Target value inputs for optional additional heating and
additional cooling.
• Target value input for optional switch-over to a lower dry
air volume.