3.1.2
Assemblies Pumpfix F for exposed installation
1
Pump unit
2
Alarm probe
3
Backwater flap
4
Motor-driven flap unit
5
Backwater probe
2019/03
Installation
1
2
Fig. [7]
33 / 140
3.2
Installation suggestion "black tub"
Schematic
illustration
5
4
3
1 Pumpfix F
2 Sealing gasket set art. # 83 073: extension section with flange and counterflange (for connection to an
on-site sealing sheet)
3 Extension Section art. # 83 070
a Tiles
b Screed
c Insulation
d Concrete floor
e Seal
010-843
010-843
Installation
BWS*
a
b
c
d
e
f
3
1
Fig. [8]
f Protective concrete
g Control unit
h Cable conduit
BWS* Design flood
34 / 140
g
h
2
2019/03