Scope of delivery

Check the system and all components supplied for completeness and for any faults
1.5.1
Variant Pumpfix F for underground installation
1
Drain body
3
Upper section, with inflow cover
5
Extension section (optional, max. 2 units)
20
Pump unit
26
Motor-driven flap unit
37
Sealing gasket
41
Cable duct
56
Inflow side
57
Outlet side
58
Electronic equipment
1.5.2
Variant Pumpfix F for exposed installation
1
Drain body
20
Pump unit
26
Motor-driven flap unit
56
Inflow side
57
Outlet side
58
Electronic equipment
2019/03
Introduction
5
20
37
1
56
20
56
29 / 140
2

Safety

2.1

Correct use

The backwater pumping station serves as a draining system for wastewater with and without sewage, domestic
and industrial wastewater.
3
2.2

Staff selection and qualification

37
Persons who install the backwater pumping station must
be at least 18 years old.
58
have been sufficiently trained and be sufficiently qualified for the respective tasks.
be familiar with and follow the respective technical rules and safety regulations.
26
Qualified staff are members of staff who, on the basis of their training and experience as well as their knowledge of
41
the relevant instructions, valid standards and accident prevention regulations, can carry out the required tasks and
both recognise and avoid any possible hazards.
Work on electrical components may only be carried out by specially trained specialist staff and under adherence to
57
all the valid accident prevention regulations (UVV).
Fig. [4]
2.3

Organisational safety measures

The operating and maintenance instructions must always be kept available.
2.4

Risks caused by the product

2.4.1
Risk caused by special location / ambient conditions
Risk caused by toxic and hazardous vapours, gases and substances (e. g. bacteria, viruses). If the backwater
58
pumping station is located in an inspection chamber, any necessary work must always be done by specialist
staff (see 2.2).
26
2.4.2
Risk of electric shock when plug has been screwed off
There is a risk of electric shock at the control unit if the plug for power supply to the pumps has been
dismantled. The union nut on the electric plug must be fitted so tightly that it cannot be loosened without a tool
(e.g. by children).
1
57
Fig. [5]
2.4.3
Risk caused by hazardous atmosphere
There is a risk of a hazardous atmosphere occurring during work. Make sure the system is well aerated and use
safety equipment such as e.g. a multi-gas warning device if appropriate.
010-843