12. AUTOMATIC SWING DOOR ROUTINE MAINTENANCE PLAN
To ensure proper operation and safe use of the automatic swing door, as required by European standard EN16005, the
owner has to perform routine maintenance by qualified personnel.
Except for routine cleaning of the door, the responsibility of the owner, all maintenance and repair work must be carried out
by qualified personnel.
The following table lists tasks related to routine maintenance, and the frequency of intervention related to an automatic
swing door operation with standard conditions. In the case of more severe operating conditions, or in the case of sporadic
use of the automatic swing door, the frequency of maintenance can be consistently adequate.
Task
Remove the power supply, open the automation and perform the following checks
and adjustments.
- Check all screws fastening of components within the automation.
- Check the state of wear of the hinges (if necessary replace them).
- Verify correct mounting of the arm on the door.
- In the case of SW4 automation, check the correct force of the closing spring.
- If present, verify proper engagement of the electric lock.
Connect the power supply and perform the following checks and adjustments.
- Check the correct operation of the control devices and safety.
- Check the detection area of the security sensors complies with the requirements
of the European standard EN16005.
- If present, verify the correct operation of the electric lock.
- If present, verify the correct operation of the battery power device (if necessary
replace the battery).
All maintenance, replacement, repair, update, etc.. must be written into the proof book, as required by European standard
EN16005, and delivered to the owner of the automatic swing door.
For repairs or replacements of products, original spare parts must be used.
12.1 DISPOSAL OF PRODUCTS
For correct disposal of electrical and electronic equipment, batteries and accumulators, the owner must
deliver the product to special "collection centres" provided by municipalities.
FA00008-EN v.7 – 05/2017
33
Frequency
Every 6 months or every 500.000
cycles.
Every 6 months or every 500.000
cycles.
Note: the verification of the
automation security functions and
safety devices must be made at least
1 time per year.
CAME S.p.A.