7.3 ELECTRONIC CONTROL TERMINALS
Note: The terminals with the same number are equivalent.
The electronic control comes with the jumpers on the terminals with an asterisk [*]. When connecting safety devices remove
the jumpers of the corresponding terminals.
Terminals
Description
0 – 1
Output 12 Vdc for external powering accessories. The maximum absorption of 1 A corresponds to the
sum of all the terminals 1 (+12V).
1 – 3A
Contact N.O. opening A side (interior side).
1 – 3B
Contact N.O. opening B side (outer side).
1 – 8A
Closing safety contact N.C. The opening of the contact causes the reversal of the movement.
Note: connect safety devices with test (see terminal 41), and remove the jumper 41 - 8A.
1 – 6A
Opening safety contact N.C. The opening of the contact stops the movement during the opening phase;
the door closes after 3s. If the automation is closed, the opening of the contact prevents the opening.
Note: connect safety devices with test (see terminal 41), and remove the jumper 41 - 6A.
41
Output test (+12 V). Connect the safety devices with test (in accordance with EN 16005), as indicated in
the following chapters.
Note: in case of devices without test, connect the N.C. contact to terminals 41 - 8A or 41 - 6A.
1 – G1
Input terminal provided for general use.
0 – G1
Output terminal (12 Vdc, 20 mA max) provided for general use.
Using the ADV > STG1 menu you can choose a specific function to the G1 terminal.
1 – G2
Input terminal provided for general use.
Using the ADV > STG2 menu you can choose a specific function to the G2 terminal.
1 – 29
Reset contact N.O. Closure and release the contact starts the learning operation of the door.
0 – 1 – H – L
Bus connection to the function selector.
+LK / -LK
Output 12V-24V (1A max) for electric lock.
SD
Standard admission for memory cards Micro SD. Allows saving the door settings and loading the firmware
updates.
Buttons
Description
OPEN
Open the door.
↑
Scroll the menu and increase of selected values.
↓
Scroll the menu and reduction of selected values.
ENTER
Button to select the menu and save the selected data.
ESC
Exit the menu.
FA00008-EN v.7 – 05/2017
17