4.2 INSTALLATION OF PBB2 AUTOMATION WITH 001PBBA02 ARTICULATED ARM
Use the articulated arm to push with doors which open outside (view from the automation).
Remove the cover and fix the automation in a stable and leveled way to the wall using the measurements shown in the
figure; refer to the axis of the door hinges.
Fix the bracket of the articulated arm on the door, using the measurements shown in the figure.
Note: if necessary, you can change the measure H, between the automation and the door,
codes listed in the
table.
(H)
PBB2 automation
28
001PBBA02 + 001PBBA06
45
001PBBA02
62
001PBBA02 + 001PBBA08
Fix the articulated arm to the automation, and fix the other end of the articulated arm to the door.
Move the door in the closed position, and adjust the length of the half-arm [A] so that the angle between the two half-arms
[A] and [B] is the greater possible.
(*) To increase the opening force it is possible to reduce the angle and reduce the measurement of fixing of the articulated
arm, as shown in figure.
Move the door manually, and verify the correct opening and closing smoothly.
Install the opening mechanical stop (not supplied by us).
Note: the mechanical stop on the floor must be fixed in a visible position and must not create tripping hazard.
CLOSING OF THE AUTOMATION COVER
Fix the cover to the heads at the lower holes (or at the lateral holes), using the screws 2,9 x9,5 not supplied by us.
FA00008-EN v.7 – 05/2017