7. ELECTRICAL CONNECTIONS
Rif.
Code
1
2
3
4
001PBBA03
5
001PBBA05
6
7
7.1 GENERAL SAFETY ELECTRICAL PRECAUTIONS
Installation, electrical connections and adjustments must be completed in conformity with Good Working Methods and with
regulations in force.
Before making power connections, check that the rating corresponds to that of the mains supply. A multipolar disconnection
switch with a contact opening gap of at least 3 mm must be included in the mains supply. This switch must be protected from
unauthorized activations.
Check that upstream of the electrical installation an adequate residual current circuit breaker and an overcurrent cut out are
fitted.
When requested, connect the automation to an effective earthing system carried out as indicated by current safety
regulations.
During installation, maintenance and repair operations, cut off the power supply before opening the cover to access the
electrical parts.
To handle electronic parts, wear earthed antistatic conductive bracelets. CAME S.p.A. declines all responsibility in the event
of components which are not compatible with the safe and correct operation of the product.
For repairs or replacements of products only original spare parts must be used.
7.2 POWER SUPPLY ELECTRICAL CONNECTION
Use the supplied cable for connection to electricity.
If the path of the power cord is outer portion automation, drill the cap on the suitable area, and route the power cable
through a channel (not supplied by us) to the junction box.
Make sure there are no sharp edges that might damage the power cable.
The connection to the mains supply in the outer portion automation, should be an independent channel, separated from the
connections to control and safety devices.
FA00008-EN v.7 – 05/2017
Terminals
Description
MAINS IN
Cable for connection to the power supply.
Switching power supply 36V 65W (for PBB2 automation)
PWR
Switching power supply 36V 75W (for PBBS2 and PBB3 automation)
Electronic control
Brushless motor (for PBB2 automation)
MOT
Brushless motor (for PBBS2 and PBB3 automation)
ENC
Angular sensor
Battery power device (for PBB2 automation)
BAT
Battery power device (for PBBS2 and PBB3 automation)
FUSE
Battery fuse 5x20 - F10A
MOT
Braking card (for PBBS2 automation)
16
CAME S.p.A.