6. ELECTRICAL CONNECTIONS OF ELECTRIC LOCK
The automations for swing doors are compatible with most of the electric locks available in the market. Verify that power
supply of the electric lock is 12Vdc or 24Vdc, and that the maximum current is 1 A.
- Connect the electric lock to terminals LK + and –LK of the CB03 electronic control.
- Set the electric lock power supply, using menu: ADV > LKPW > 12Vdc or 24Vdc.
- Set the type of electric lock operation, using menu: ADV > ELLK > LOCK or SAFE/AUTO.
- Set the operating time of the electric lock, using menu: ADV > TRLK > from 0,5 to 5,0 seconds.
- Set the start of the door opening delay time, using menu: ADV > TALK > from 0,5 to 5,0 seconds.
In the figure are shown the timing of the electric lock operation:
A = start of opening pulse and electric lock power supply on/off,
B = start of door opening,
C = end of electric lock power supply on/off.
6.1 ELECTRICAL CONNECTIONS OF ELECTROMAGNET 12 Vdc
In case the electromagnet used requires a stabilized power supply of 12 Vdc (with absorption of 500 mA max), use the KITL
relay card and make the connections shown in the figure.
- Set from menu: ADV > ELLK > SAVE or AUTO.
- Set from menu: ADV > LKPW > 12.
FA00008-EN v.7 – 05/2017
15
CAME S.p.A.