CAME FLUO-SW Instructions D'assemblage Et D'installation page 59

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Display
Description
TALK
Time advance operating electric lock. Choose between the minimum and maximum values:
LOCK
minimum value = 0,5 s
ADVANCE
maximum value = 5,0 s
TIME
TRLK
Operating time of the electric lock. Choose between the minimum and maximum values:
LOCK
minimum value = 0,5 s
OPERATION
maximum value = 5,0 s
TIME
LKSH
Setting of closing push for hooking the electric lock. Choose between the following values:
LOCK
NO = no push
HOOKING
MIN = light push
MED = medium push
MAX = heavy push
PUCL
Setting the push on the closed mechanical stop. Choose between the following values:
PUSH DOOR
NO = no push
CLOSED
MIN = light push
MED = medium push
MAX = heavy push
XMAX = very heavy push
PIPP
Setting of the opening push. Choose between the following values:
PUSH DOOR
NO = no push
OPEN
YES = push enabled (disabled with ANG)
HOLD
Setting the push of keeping the door open. Choose between the following values:
HOLD DOOR
NO = no push
OPEN
MIN = light push
MED = medium push
MAX = heavy push
PUGO
Push opening activation. Choose between the following values:
PUSH & GO
NO = off
YES = active (disabled with PWAS)
PWAS
Manual operation of the door in servo assisted mode (Note: any safety devices are disabled). Choose
POWER
between the following values:
ASSIST
NO = disabled manual operation power-assisted
MIN = minimum manual operation power-assisted
MED = medium manual operation power-assisted
MAX = maximum manual operation power-assisted
ANG
Selecting of the door opening angle. Choose between the following values:
OPENING
NO = the door opens up to the mechanical opening stop
ANGLE
5 ... 240 = the door opens up to the selected angle
(Note: the value indicated refers to the arm angle and not to the door angle)
TAKO
Open door time setting, after the 1-KO command. Choose between the minimum and maximum:
KO-CLOSING
minimum value = 1 s
TIME
maximum value = 30 s
NO = the door is always open
NO = see MENU > TAC
MOT
Setting the manual friction of the door, by means of the electrical connection of the motor windings.
MOTOR
Choose between the following values:
CIRCUIT
OC = manual door opening without friction (motor with open circuit windings)
SC = manual door opening with friction (motor with short-circuit windings)
FA00008-EN v.7 – 05/2017
25
Factory settings
0.5
0.5
MED
MIN
NO
MED
YES
NO
NO
NO
SC
CAME S.p.A.

Publicité

Table des Matières
loading

Table des Matières