9. The brush circuit breaker will trip if the brush is
obstructed. To reset the circuit breaker, unplug the
power cord, remove the obstruction and reset the 5
amp circuit breaker button (Figure 18). If the circuit
breaker does not reset immediately, allow the
motor to cool.
FOR SAFETY: Before removing obstruction from
brush unplug power cord from wall outlet.
FIG. 18
10. When transporting machine, roll the machine on
both the main and rear tilt wheels.
FOR SAFETY: When transporting machine, do not
wheel up or down stairs.
CLEANING WITH ACCESSORY TOOLS (Option)
1. Connect the accessory tool hoses to solution hose
coupler and vacuum hose port located at the front
of the machine (Figure 19).
FIG. 19
2. Fill the solution tank (See FILLING SOLUTION
TANK on page 6).
Tennant E5 (03- 08)
3. Press the main power switch to the on ( I ) position
(Figure 20). Press the cleaning mode switch
towards the accessory tool mode (Figure 21).
FIG. 20
4. Operate the accessory tool (Figure 22).
WARNING: Fire or Explosion Hazard, Do Not
Use or Pick Up Flammable Materials.
FIG. 22
OPERATION
EN
FIG. 21
9