SECTION 7 −
7-1. Routine Maintenance
!
Disconnect Power before maintaining.
.
Service equipment more often if used in severe conditions.
.
To make cleaning easier, apply anti-spatter spray to the extraction hood.
n = Check
* To be done by Factory Authorized Service Agent
Daily
n Filter Gauge
Every
Month
~ Outer Surfaces
Every
3
Months
l Unreadable Labels
Every
6
Months
~ Inside Unit
7-2. Overload Protection
USER SERVICING INSTRUCTIONS (MAINTENANCE)
Z = Change
~ = Clean
n Free Movement Of
Base Assembly
~ Inside of Extraction Arm
With Warm Water And
Detergent
~ Sealed Bearings − No
Oil Needed
1
l = Replace
n Extraction Arm Hood
n Extraction Arm Ducts
And Joints Stay In Position
And Tubing
É É
nl Fume Extractor Spark
nl Filter
Guard
~ Inner
Surface Of
Hood
~ Swivel
Base
Bearings
!
Turn off unit and disconnect
input power cord.
1
Circuit Breaker CB1
CB1 protects the blower motor from
overload. If CB1 opens the blower
motor will not run.
To access CB1, reach under front
panel.
To reset CB1, reach under front pan-
el and place CB1 in the On (up) posi-
tion.
.
If a fuse or circuit breaker opens,
it usually indicates a more seri-
ous problem exists. Contact a
Factory
Authorized
Service
Agent.
OM-239 025 Page 17