The motor revolves irregularly
The motor leaks
11
The motor revolves
irregularly
Pump flow is
irregular
NO
Excessive internals
leaks
The motor leaks
The housing
pressure is
too high
NO
The seals are
deteriorated
NO
The assembly
is incorrect
DOC-REPAIR-MS25-MS125-FR-EN
YES
Check the pump flow
YES
Replace the cylinders block
and valving assembly
YES
Check the drain circuit
and filter condition
YES
Replace the seals
YES
Check tightening of mounting
screws, bleed screws
and hydraulic fittings
POCLAIN HYDRAULICS
800378131M