Installation - salmson SIRIUX Série Manuel D'installation Et Mise En Service

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English

7.1 Installation

WARNING! Risk of injury!
Incorrect installation can result in injuries.
• There is a crushing hazard!
• There is a risk of injury due to sharp edges/burrs. Wear appropriate protec-
tive clothing (e.g. safety gloves)!
• There is a risk of injury hazard due to the pump/motor falling! Use suitable
lifting gear to secure the pump/motor against falling!
CAUTION! Risk of damage to property!
Incorrect installation can result in damage to property.
• Have installation work performed by qualified personnel only!
• Observe national and regional regulations!
• When the pump needs to be transported, it may be carried only by the motor/
pump housing. Never at the module/terminal box or pre-assembled cable.
• Installation within a building:
Install the pump in a dry, well-ventilated room. Ambient temperatures below -
10°C are not permissible.
• Installation outside a building (outdoor installation):
• Install the pump in a sump (e.g. light sump, annular sump) with cover or in a
cabinet/housing as weather protection.
• Avoid exposure of the pump to direct sunlight.
• The pump requires protection so that the condensate drain grooves are not
contaminated. (Fig. 6)
• Protection of the pump against rain. Dripping water from above is permitted
provided that the electrical connection has been established in accordance
with the installation and operating instructions and the terminal box has been
properly sealed.
CAUTION! Risk of damage to property!
Ensure sufficient ventilation/heating if the ambient temperature exceeds/
falls below the permitted limit values.
• Carry out all welding and soldering work prior to the installation of the pump
CAUTION! Risk of damage to property!
Contamination from the pipe system can destroy the pump during operation.
Before installing the pump, flush the pipe system.
• Provide check valves upstream and downstream of the pump.
• Attach pipework to the floor, ceiling or wall using appropriate fittings so that
the pump does not bear the weight of the pipework.
• When installing in the feed of open systems, the safety supply must branch off
upstream of the pump (DIN EN 12828).
• Install the pump at an easily accessible point so that it can be easily checked or
replaced at a later time.
64
Pompes Salmson 01/2013