After the completion of the proving program

An extra program is built in which begins to cool down the products after the end of the proving
process. This stops the fermentation in the products.
Mode of operation and signals
The time after the completion of the program is called extra time. When the extra time has
expired, the cooling begins.
The default value of extra time is 10 minutes, but it can be regulated from 0 to 30 minutes.
When the time is set to 0 minutes, the extratime program is not active, and the device continues
the proving program without pause.
This corresponds to older program versions, such as G 108.
When the extra time program is active, the red LED lamp flashes. This is to warn the user of the
extended time for the proving process.
When cooling sequence begins, the refrigeration system begins to cool the products, and brings
the temperature down to the standard value of +2°C.
Now it is the yellow LED lamp that flashes, to warn that the products have been through both a
normal proving process and the extra time. The yellow LED lamp continues to flash until the
device is stopped completely. This is done by pressing the P button.
Interruption of the extratime and cooling
While the program is engaged in either the extra time or the actual cooling phase, the user can
choose to press either the P or the S button.
Pressing the P button will stop the device completely.
If the S button is pressed, the device will return to the GA program and will continue to run this.
If the S button is pressed during the extra time or the cooling phase, the red lamp will glow
constantly, and the other lamps will be turned off.
Setting extra time and cooling
The settings of the two new values can be adjusted via the hidden service menu of the control
system.
Interrupting the automatic program before the program concludes and extratime begins
If the user returns to the device before the conclusion of the complete program, the user can
choose to push the S button to cancel the complete program.
The program will now continue its normal functioning with the proving program. For this to be
done, the proving program must have entered the last quarter of its cycle.
Information on the time of completion is removed through this choice, and only the temperature
and humidity are shown, alternately.
The two green lamps and the yellow lamp are also turned off.
54