Water drain
Water connection
Humidifier
The cabinet is equipped with a humidifier that provides steam during proving. The humidifier
consists of a water tank heated by electrodes. From the tank, steam is led into the cabinet
through a pipe. The tank is automatically filled from the water supply.
The tank can be flushed by switching the cabinet off at the main switch and then switching it on
again. In addition, the system is automatically flushed regularly depending on water quality.
For further information on servicing and maintaining the humidifier, please
consult the "Service and operation manual". For maintenance of the humidifier,
request service assistance.
765041584
Defrost water and water flushed from the
humidifier are led away through a pipe on the
rear of the cabinet. A water seal must be
installed between cabinet and drain.
To provide steam during proving, the humidifier must
be connected to a water supply.
Please note the following:
The electrical conductivity of the water must be in the
range: 50-800 µS/cm.
The temperature of the water must not exceed 60°C.
The water pressure must be in the range 1-10 bar.
A shut-off valve, a check valve, and a filter if
necessary, must be fitted to the supply pipe.
Rev 000
56