Télécharger Imprimer la page

Site Preparation; Combustion Air Inlet; Préparation Du Chantier; Arrivée D'air Pour La Combustion - Stuv 30-compact haut Manuel D'installation

Publicité

SITE PREPARATION

Combustion air inlet

1
Ø 120
b
2 3/8"
9 1/2"
3
4
a
b
The stove requires air for combustion (particularly when
working in open-fire mode).
The ideal solution
The Stûv 30-compact is designed to be directly connected
to an outside air inlet (independent of the air in the house).
We recommend this set-up. The connection can be made
below the stove [diagrams 1a & 2] or at the back [diagram
1b & 3].
If the stove is not connected directly to an outside air
inlet...(optional)
A sufficient air inlet (Ø 2-1/2") should ideally be created
close to the stove [diagram 4].
This air inlet comes from a ventilated empty space, a
ventilated room (cellar) or from outside.
This set-up is mandatory in some countries or localities.
2
a
a
b
4
5
Ø 120
PRÉPARATION DU CHANTIER
Arrivée d'air pour la combustion
3
Le foyer a besoin d'air pour la combustion
(particulièrement lorsqu'il fonctionne à feu ouvert).
La solution idéale
Le Stûv 30-compact est conçu pour être connecté
directement à une arrivée d'air extérieur (indépendant de
l'air de la maison). Nous recommandons cette disposition.
La connexion peut se faire par en dessous du foyer
[schémas 1a et 2] ou par l'arrière [schéma 1b et 3].
Si le foyer n'est pas directement raccordé à une arrivée
d'air extérieur... (facultatif)
Une arrivée d'air suffisante (ø 2-1/2"), doit idéalement
déboucher à proximité du foyer. [schéma 4].
Cette arrivée d'air proviendra d'un vide ventilé, d'un local
ventilé (cave) ou de l'extérieur.
Cette disposition est obligatoire dans certains pays ou
localités
Stûv 30-compact haut - 02/14
7