Dimensions & clearances
Stûv 30-compact H
The clearances are indicated for all types of combustible
materials (e.g.: wood, gypsum, etc.).
Front clearance: 48"
Rear clearance: 8"
Side clearance: 8"
Minimum ceiling height: 96"
A flameproof protective material (no minimum R-value
must be laid on the ground in front of the fireplace over a
length of 18" in front of the glass and 8" on each side of
the glass.
CLEARANCES MAY ONLY BE REDUCED BY MEANS
APPROVED BY THE REGULATORY AUTHORITY.
We recommend to store solid fuel (wood logs) in a clean
and dry environment. Caution: do not place such fuel
within space heater installation clearanes or within the
space required for charging and ash removal.
Stûv 30-compact haut - 02/14
6
SN 131766 - ...
17"2/4
9"1/8
≥ 8"*
Dimensions & dégagements
Ø 6"
2"3/8
≥ 8"*
Les dégagements indiqués sont pour tout matériaux
combustible (ex.: Bois, Gypse, etc.).
Dégagement avant : 48"
Dégagement arrière : 8"
Dégagement des côtés : 8"
Hauteur minimum du plafond : 96"
Un matériel de protection incombustible (pas de valeur-R
minimal) doit être placé au sol à l'avant de l'appareil sur
une longueur de 18" devant la vitre et 8" de chaque côté
de la vitre.
LES DÉGAGEMENTS PRESCRITS NE PEUVENT ÊTRES
RÉDUITS QUE PAR DES MOYENS APPROUVÉS PAR UNE
AUTORITÉ DE RÉGULATION.
Nous vous recommandons de ranger le combustible solide
(bois de corde) dans un environnement propre et sec.
Attention : Ne placez pas ce genre de combustible dans
l'espace de dégagement d'instalation du poêle ou dans
l'espace de chargement ou de décendrage.