Combustion air connection
Air drawn from outside
If the freestanding fireplace is
positioned on a Stûv base with a
drawer or on a Stûv 16 H base, please
consult the instructions which come
with these accessories.
The combustion air is drawn from
outside by means of a duct [diagram
1] connected to the support plate.
Remove the plug [photo 2] and the
cover at the front [photo 3].
Fit the duct over the sleeve [photo 4]
and secure it with a clamp collar
[photo 5] with the collar attachment
turned towards the back of the
freestanding fireplace
Insert the 2 M4 screws with
hexagonal heads into the cover at the
front, put the sleeve between the 2
screws [photo 6] and then fasten it all.
Ensure the plate is level and attach it
to the base [photo 7].
Combustion air is drawn from
the room where the freestanding
fireplace is installed
Make sure there will be adequate
air renewal once the freestanding
fireplace is operating.
Remove all of the covers of the
support plate [photo 8].
1
3
5
7
19
2
4
6
8