Checking Gas Pressure - Angelo Po 1G1FAPG Manuel D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

To carry out this operation, proceed as follows.
1 - Remove the bottom plate (C) and the grid (D)
from the oven and clean them thoroughly.
2 - Clean the inside parts of the oven to remove any
deposits which may impair its operation.
3 - Dry the surfaces and reassemble the compo-
nents.
To carry out this operation, proceed as follows.
1-Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the screws (B) and remove the con-
trol panel (C).
4 - Undo the screw (D) of th e pressure con-
nection.
5 - Connect the pressure gauge (E) to the
pressure test point (F).
6 - Turn the gas supply tap back on.
IT
IT
GB
GB
DE
DE
FR
FR
ES
ES
English
CLEANING OVEN

CHECKING GAS PRESSURE

A
D
C
7 - Light one of the burners, turn the knob to the full
flame setting (see page 10) then check that the
pressure reading is the same as the values pro-
vided in the table (see back of manual).
8 - Switch off the burner, turn off the gas supply tap
and disconnect the pressure gauge.
9 - Restore the initial conditions af ter completing
the operation.