Correcty Assembly Of The Actuator On The Window Frame; Electrical Connection; Control Devices - TOPP C130 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

%
Fig.31 – Mark the midline "Z" on the window with a
pencil;
%
Fig.32 – Apply the template on the window frame
aligning it with the previously drawn centre line "Z";
CAUTION: for non-coplanar window frames, it is
necessary to cut the template concerned part and
to apply it on the window frame paying attention to
keep it in the same reference position.
%
Fig.33 – With a suitable drill, create on the window
frame holes having the related diameter, given on the
template;
%
Fig.34 ÷ 36 –With the suitable screws tighten the two
brackets for the dome window assembly (AF Ø 4,8x16)
and the snap fasterner (AF Ø4,2x19);
%
Fig.37 – Insert the two pairs of clamps for the dome
window applications, fitting them in the actuator slider
adjacent to the chain terminal, then close them partially
with the screw and nut in the package;
%
Fig.38 – Position the clamps symmetrically about
160mm on either side of the chain terminal midline and
tighten the screw all the way;
%
Fig.39 – Make the electrical connections as described
in para.5.6 and with reference to the wiring diagram
shown in Fig.46 for C130/230V, Fig.47 for C130/RR or
Fig.48 for C130 24V. Use the command to have the
chain run out by at least 50mm and disconnect the
power cord;
%
Fig.39 ÷ 40 – First fasten the chain terminal to the snap
fastener, then fasten the clamps to the brackets for
connection to the window;
@
Make sure the brackets for connection to the
window are correctly fastened to their clamps.
%
Connect the power cord again.
&
For correct adjustment of the window closure, see the
instructions in para.5.5.
CORRECT ASSEMBLY OF THE
5.5
ACTUATOR ON THE WINDOW FRAME
Adjusting the window closure correctly will ensure the
duration and the holding of the seals and will provide a
good functioning of the actuator.
A good method to perform a correct installation consists
in making sure that after closing the actuator the following
carried out:
-
the window seals must be pressed correctly;
22
INSTALLATION AND USE INSTRUCTIONS
-
that, with open window frame, the selected stroke is
some centimetres lower than the stroke limited by
window frame mechanical limit devices;
-
that the chain end is on the same axis of the quick
coupling. otherwise, loosen the fixing screws and
position it correctly. when the devices are not coaxial,
this may damage the actuator and the window frame;
-
that the two brackets of connection to the window
frame are aligned to each other and that the tightening
screws vre well tightened.
5.6
ELECTRICAL CONNECTIONS
The electrical connection of the actuator must be
carried out exclusively by competent and qualified
technical personnel with the professional
technical requirements provided by current laws
in the country in which the actuator is installed and
must issue a declaration of conformity to the client
for the connection and/or for the system made.
&
Any type of electrical material (plug, cable, terminal,
etc.) that is used for the connection must be suited for its
use, must have a "EC" marking and must comply with the
requirements provided by the current regulations of the
country in which the installation is made.
&
The power-supply line where the actuator is
connected must comply with the requirements provided
by the current regulations of the country in which the
installation is made; it must also meet with the technical
characteristics stated on tab.1, with the rating plate and
with the "CE" marking (par. 3.1).
&
The section of the power supply cable line must be
duly sized according to the absorbed power supply (see
rating plate and "CE" marking).
&
In order to provide an efficient division from the mains
a type-approved temporary bipolar switch (push button)
must be installed upstream from the appliance.
Upstream from the control line a power supply bipolar
main switch must be installed with opening contacts of at
least 3 mm.
& Before making any electrical connections on the
actuator, make sure it is installed correctly on the window.
& Before making any electrical connections on the
actuator, make sure the power supply cable is not
damaged. If the cable is damaged, then it must be
replaced by the manufacturer through the technical
assistance service or by technical operators.
5.7

CONTROL DEVICES

The control devices used to run the actuator must
provide the safety conditions required by the current
C130
EN

Publicité

Table des Matières
loading