3.2
NAME OF COMPONENTS AND DIMENSIONS
Fig.2a and Fig.2b show the names of the main parts that make up the actuator.
3.3
TECHNICAL DATA
Tab 1 shows the technical data that makes up actuator C130.
MODEL
SUPPLY VOLTAGE
ABSORBED CURRENT
ABSORBED POWER UNDER LOAD
MAXIMUM APPLICABLE THRUST LOAD
MAXIMUM APPLICABLE TRACTIVE LOAD
IDLE TRANSLATION SPEED
DURATION OF MAXIMUM IDLE STROKE
PROTECTION AGAINST ELECTRIC SHOCK
RAIN SENSORS INSTALLED ON THE ACTUATOR
ACTUATOR LENGHT
TYPE OF SERVICE S
PROTECTION GRADE FOR ELECTRIC APPLIANCES
ADJUSTMENT OF THE WINDOW FRAME CONNECTION
PARALLEL ELECTRIC CONNECTION OF MORE
ACTUATORS ON THE SAME WINDOW
PARALLEL ELECTRIC CONNECTION OF MORE
ACTUATORS ON DIFFERENT WINDOWS
OPERATING TEMPERATURE
Limit switch: Electronic for opening - by amperometric absorption for closing.
ACTUATOR WEIGHT WITH BRACKETS
WORKING STROKE LENGTH (NOT SELECTABLE)
MINIMUM WINDOW FRAME HEIGHT
(1)
The rain sensors are installed on the actuator mod. C130/RR for top-hinged and dome windows
(see cap.7)
(2)
Service of limited duration according to EN 60034.
(3)
Tolerance on the precision of limit switch tripping at output: ± 2 mm.
(4)
Actuator distance from the window frame opening hinge
18
(2)
2
(mm)
INSTALLATION AND USE INSTRUCTIONS
C130/RR
230V ~ 50Hz
0,12 A
25 W
300 N
200 N
8 mm/s
46 s
Class II
(1)
Si
600÷1200mm
4 min
IP 30
No
No
No
1,10 Kg (L=420mm) to 2,10 Kg (L=1200mm)
(3)
Top hung
(4)
Bottom hung
Dome
Tab. 1
C130/24V
C130/230V
24 V
230V ~ 50Hz
0,43 A
0,12 A
9 W
25 W
300 N
300 N
200 N
200 N
7,5 mm/s
8 mm/s
48 s
46 s
Class III
Class II
No
No
420÷1200mm
420÷1200mm
4 min
4 min
IP 30
IP 30
No
No
No
No
Yes
(See wiring diagram)
-5°C ÷ +50°C
240 mm
360 mm
360 mm
250 mm
900 mm
500 mm
500 mm
350 mm
EN
C130