Aurora PVI-10.0-I-OUTD-400 Manuel D'utilisation page 93

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Use and installation manual
(PVI-10.0/12.0-I-OUTD(-S)-400 Rev:1.3)
Description
Max. recommended DC
power
Rated DC power
Rated input voltage
Max. input direct voltage
Input voltage, MPPT
operating range
Input voltage, MPPT
operating range at full
power
Max. short circuit
current (of each array)
Max. operating input
current (of each array)
Max. input power (of
each channel)
PV ground fault
protection
Input channel
configuration
(1
) The total input power must remain within the recommended DC power value
(2)
The independent channel configuration cannot be used with positive grounding
setting or with floating photovoltaic generator
PVI-10.0-I
11500 W
10500 W
From 220V to 470V
(1)
Value
330 Vdc
520 Vdc
from 90 Vdc to 520 Vdc
24A
29 Adc
6800 W
Isolation detection system + PTC
Parallel / Independent
92
97
Page
of
Value
PVI-12.0-I
13500 W
12300 W
From 250V to 470V
25A
6800 W
(2)