Aurora PVI-10.0-I-OUTD-400 Manuel D'utilisation page 52

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Use and installation manual
(PVI-10.0/12.0-I-OUTD(-S)-400 Rev:1.3)
What to do after an isolation fault has been detected
When the red LED turns on, try to reset the fault indication by
using the multifunctional ESC button at the side of the LCD
display. If AURORA reconnects to the grid normally, the fault
was due to temporary circumstances. It is recommended to
allow a specialized technician to inspect the machine if the fault
continues to occur.
If AURORA does not reconnected to the grid, it is necessary to
put AURORA into a safe condition by isolating it on both the
DC and AC sides, and contacting an authorized centre in order
to have the fault repaired.
G
5) Anomaly-Fault indication
Each time that AURORA check system detects an anomaly or
Y
fault in the operation of the monitored system, the yellow LED
R
lights up and stays on, and a message indicating the type of
problem detected will appear on the LCD display.
G
6) Internal ventilation fault
Y
Indicates that the internal ventilation is not functioning correctly.
This should not cause problems, as the fan is only activated when
R
high output power is combined with high temperatures.
G
7) Grid disconnection
When the system is functioning normally, and a grid failure event
Y
R
occurs, the yellow LED will immediately light up and stay on,
and the green LED will flash.
the experience or qualifications necessary to work safely on the
system.
51