E-tot : Total energy produced since installation
E-par
Partial energy produced during the period selected by us
:
P-out : measured instant output power value
In the second line of the display, only the higher of the two temperatures is shown:
T-boost1: booster channel 1 switching device temperature
T-boost2: booster channel 2 switching device temperature
Ppk: maximum peak power value achieved since the "partial" function was
activated.
Ppk-Day: indicates the maximum peak power value achieved during the day. The
counter is reset when the unit is shut down.
VoutR
230 V
Vout AvgR 230 V
VoutX: measured instant voltage of grid phase / neutral
Vout AvgX: average voltage of grid phase / neutral calculated over the last 10
minutes of inverter operation
VoutRS
400 V
Vout AvgR 230 V
VoutXX: instant value of chained voltage
IoutR
5.6 A
FoutR
50.01 Hz
Iout: measured instant grid current value
Fout: measured instant grid frequency value
P-out 0 W
T-boost1 - °C
Ppk W
Ppk-Day ............W
VoutS
230V
Vout AvgS 230V
VoutST
400V
Vout AvgS 230V
IoutS
5.6 A
FoutS
50.01 Hz
57
Page
of
VoutT
230 V
VoutAvgT 230 V
VoutTR
400V
VoutAvgT 230 V
IoutS
5.8 A
FoutS
50.01 Hz