Use and installation manual
(PVI-10.0/12.0-I-OUTD(-S)-400 Rev:1.3)
DC/DC Fail
Wrong Mode
Over Temp.
Cap. Fault
Inv. Fail
Int.Error
Ground F.
Int.Error
Int.Error
Int.Error
Int.Error
Int.Error
Int.Error
Int.Error
Int.Error
Int.Error
Int.Error
Fan Fail
Int.Error
IGBT not ready
Remote OFF
Int.Error
Int.Error
Int.Error
//
E012
//
E013
//
E014
//
E015
//
E016
//
E017
//
E018
//
E019
//
E020
//
E021
//
E022
//
E023
//
E024
//
E025
//
E026
//
E031
//
E032
W010
//
//
E033
//
E034
//
E035
//
E036
W012
//
W013
//
Internal error
Wrong Input setting (Single instead of dual)
Wrong setting of inputs (single channel
instead of 2 channels)
Overtemperature
Internal temperature too high
Bulk Capacitor Fail
Bulk capacitor failure
Internal error
Internal error
I leak fail
Leakage current too high or incorrect ground
mode
Ileak Sensor fail
Leakage current error
Output relay self test fail
Output relay self test failed
Output relay self test fail
Output relay self test failed
Output relay self test timeout
Output relay self test failed
Dc-Injection Error
Internal Error
Riso Low (Log Only)
Isolation resistance low (log only)
Internal error
Output relays fail
Output relays broken down
Unbalanced output currents
Unbalanced output currents
Fan Fail (No disconnection)
Defective fan (log only
Under Temperature
Internal temperature too low
Internal Error
Remote Off
Remote shut-down
Vout Avg
Average output voltage out of range
Clock Battery Low (No disconnection)
Clock battery low
Clock Failure (No disconnection)
Clock not working
53
97
Page
of