Tableau G-1 : Messages d'erreur POST
Message
Description
1785
Slot 1 Drive Array not Configured
(Suivi de l'une des précisions
suivantes):
(1) No drives detected
(2) Drive positions appear to have
changed. Run the Array Diagnostics
Utility (ADU) if previous positions are
unknown, then turn system power OFF
and move drives to their original
positions.
(3) Configuration information indicates
drive positions beyond the capability of
this controller. This may be due to
drive movement from a controller that
supports more drives than the current
controller.
(4) Configuration information indicates
drives were configured on a controller
with a newer firmware version.
Manuel de l'utilisateur du contrôleur Compaq Smart Array 5300
suite
Signification et action recommandée
1) Mettez le système hors tension et
vérifiez les branchements des câbles SCSI
afin d'être certain que les disques sont
connectés correctement.
(2) Exécutez l'utilitaire de diagnostics ADU
si les emplacements précédents sont
inconnus. Ensuite, mettez le système hors
tension et déplacez les disques jusqu'à leur
emplacement d'origine.
(3) Pour éviter la perte de données, mettez
le système hors tension et connectez à
nouveau les disques au contrôleur
d'origine.
(4) Pour éviter la perte de données,
connectez à nouveau les disques à leur
contrôleur d'origine ou mettez le
microprogramme du contrôleur au même
niveau que celui du contrôleur d'origine à
l'aide du ROMPaq Options.
Appuyez sur la touche F1 pour reprendre.