English
1. General
About this document
The language of the original operating instructions is
French. All other languages of these instructions are
transations of the original operating instructions.
These Installation and Operating Instructions form
an integral part of the unit. They must be kept close
to the unit and in readiness whenever required.
Precise observance of these instructions is a
precondition for use of the unit for the intended
purpose and for its correct operation.
These Installation and Operating Instructions
conform to the relevant version of the equipment
and the underlying safety standards valid at the
time of going to press.
Installation and commissioning only
by qualified personnel
(table 1)
Pumping medium allowed
Permissible media temperature
Maximum ambient temperature
Maximum permissible working pressure:
Mains voltages
Standard motor
Speed
Mains fuse protection
Insulation class
System of protection
1) When using a water-glycol mixture containing up to 40% glycol (or media with a viscosity different to that of pure water, the flow data for the pump must be adjusted according to
the higher viscosity of the flow media, regardless of the percentage of the viscous matter. Only use branded goods with corrosion protection-inhibitors, follow manufacturer's
instructions.
2) If other and also aggressive chemical fluids are to be pumped, be sure to follow catalogue instructions and first obtain the approval of Wilo.
Principal dimensions and connection dimensions (Table 2, see also Fig. 3):
Types
A
MVI
1602 1614
DN50
194
3202 3216
DN65
235
5202 5212
DN80
260
7001 7007
DN100
261
9501 9506
DN100
261
When ordering spare parts, please give all the information on the pump/motor rating plate.
2
at the inlet (inlet pressure see paragraph 5.3)
at the outlet, for a 2 pole motor
at the outlet, for a 2 pole motor
DM: for < P2 ≤ 4 kW
for P2 ≥ 5,5 k
for P2 ≤ 5,5 kW
for P2 ≥ 7,5 kW
2 pole version
4 pole version
PN16 version
B
Y
W
Z
mm
252
20
215
130
235
35
195
195
260
30
220
220
350
45
280
199
350
45
280
199
1.1 Uses
The pump is suitable for hot and cold water
and other fluids free from mineral oil and without
abrasives or long-fibred substances. The main
areas of use are in water supply installations, as a
booster pump, as a boiler feeder pump, in indus-
trial circulation systems, in process technology,
in cooling water systems, in fire extinguishers
and in washing and sprinkler installations.
1.2 Product data
1.2.1 Connection and electrical data (table 1)
E
F
J
K
A
300
90
125
4x18
194
320
105
145
4x18
260
320
105
160
8x18
260
380
140
180
8x19
261
380
140
180
8x19
261
Drinking water in acc. with Drinking Water Order
Heating water / service water
Condensate
Water/glycol mixture
Other liquid media
-15°C to +120°C (Follow catalogue instructions)
+40°C
16/10 bar
16/25 bar
16/16 bar
3 ~ 230/400 V ± 10%, 50 Hz
3 ~ 400 V ± 10%, 50 Hz
V 18 Standard motor
V 1 Standard motor
2900 RPM
1450 RPM
see motor rating plate
F
IP 55
better protective systems available
PN25 version
B
Y
W
Z
E
mm
252
20
215
130
300
260
35
220
220
320
260
30
220
220
320
350
45
280
199
380
350
45
280
199
380
WILO SE 11/2010
1
)
2
)
F
J
K
90
125
4x18
120
145
8x18
105
160
8x18
140
190
8x23
140
190
8x23