Water-Cooling - Migatronic SIGMA2 300 COMPACT/S Mode D'emploi

Masquer les pouces Voir aussi pour SIGMA2 300 COMPACT/S:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21
Wire cabinet panel
1
2
3
4

Water-cooling

1
The indicator above the keypad will be switched
on when watercooling has been selected.
Watercooling continues 3 min. after welding has been
completed.
Special configuration of
2
internal/external control
A short pressure on the keypad changes
between internal and external control. The indicator
above the key is switched on/flashes, when external
control has been selected.
Configuration:
Press the
key for > 5 seconds to get the following
options (MIG/MAG):
1 = Dialog torch (factory setting)
2 = ERGO 3 sequence torch.
Model XMA
(not possible in Basic control
panel)
Article no.: 80100758
3 = Remote control
4 = ERGO 1-7 sequence torch.
(not possible in Basic control
panel)
Article no.: 80100774
5 = MIG Manager®
6 = MIG-A TWIST 1-7
sequence torch version 1
(sold until November 2010)
7 = MIG-A TWIST 1-7
sequence torch version 2
(sold from November 2010).
Article no.: 80100403
When the desired figure is displayed, press the key
next to the right control knob or the
activate the function.
In position MMA (P001) and gouging (P004), it is only
possible to switch on and off the remote control, for
which reason the F50 menu cannot be opened.
Dialog torch:
Current/wire feed speed/material thickness can be
adjusted both on the left control knob internally and
on the control wheel on the welding torch.
Voltage trim/voltage/arc-adjust can be adjusted from
the right control knob internally
Sequence torch:
Selecting sequence torch (external control)
automatically defines 3/7 sequences that can only be
changed on the torch. All other settings can be carried
out on the control panel.
IMPORTANT!
It is not possible to switch between sequence numbers
1-7 (1-3 for the ERGO model XMA) if the wrong
sequence torch has been selected. Please select a
suitable type from the list.
Remote control:
Current/wire feed speed/material thickness can be
adjusted both on the left control knob internally and
from the control knob on the remote control.
Voltage/arc-adjust can be adjusted both from the right
control knob internally and from the control knob on
the remote control.
Voltage trim can only be adjusted from the remote
control.
MIG Manager®:
Please refer to the MIG Manager® quick guide.
Inching
3
The function has been used for wire inching e.g.
after change of wire. The wire feed speed can
be adjusted by pressing the keypad and simultaneously
turning the left control knob.
Gas test
4
The gas valve is opened, when the keypad
is pressed. Then gas will fill the hose before
welding.
Hold down
and press
between synergic and manual gas adjustment.
0 = manual gas control
1 = IGC
-key pad to
simultaneously to change
13

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sigma2 400 compact/sSigma2 500 compact/s

Table des Matières