Installation
Proceed as follows:
➤ Decide on the routing of the motor wire (fig. 2, page 3).
➤ Check the voltage of the blind (see cable label).
➤ Choose a location for the control device (such as switch or remote control)
which must be installed in a visible location.
➤ Connect the blind according to the circuit diagram:
– Manually switched blinds (fig. 6, page 5)
– Remotely controlled blinds (fig. 7, page 6)
– Other control system (fig. 8, page 6)
I
NOTE
Momentary operation of the switch or automation system for 500 ms will
instruct the Somfy Centralis DC IB control unit to apply power to the blind
motor in the direction selected for a maximum of 3 min. To stop the Somfy
Centralis DC IB control unit press the centre stop button.
Key to circuit diagrams:
Item
1
2
3
4
5
6
7
8
9
10
bk
rd
wh
gy
ye
16
Description
Fused 12 Vg or 24 Vg supply
(fuse rating: 2 A for 12 Vg, 1 A for 24 Vg)
Head rail motor 1
Head rail motor 2
Customer supplied switch (DPDT (double pole, double throw),
latching or momentary, 12/24 Vg, 3 A)
AP Receiver
Automation system dry contact component
Somfy Centralis DC IB control unit
Center stop function
UP function
DOWN function
black
red
white
gray
yellow
Skyscreen Powered
EN