Skyscreen Powered
I
NOTE
The motors have a built-in, self resetting thermal cut-out for safety reasons.
Prolonged use or over loading the blind could trigger the cut-out. If this
happens allow the motor to cool for a few minutes.
This product is only suitable for the intended purpose and application in accord-
ance with this instruction. Any other use, deviating from the intended use, is not
allowed! Dometic accepts no liability for any loss, damage or injury incurred,
directly or indirectly due to other as the intended use.
6
Technical description
The blinds are available for a connection to 12 Vg or 24 Vg.
The motor can be controlled using:
• Switches
• AP Remote control
• Central control systems
The number on the product label in the head rail indicates the blind type.
The dimension drawings show the required measurements for fixing with surface
covers or concealed with the boat headlining (fig. c, page 9).
7
Installation
!
WARNING! Risk of injury
Disconnect the power supply before you begin and ensure that it can not be
reconnected until installation has been completed.
7.1
Electrical installation
A
NOTICE! Risk of damage
• Ensure cables are not damaged during installation.
• Ensure that a 12 V or 24 V power supply line is available for the drive (rated
power 13.2 W) at the point of installation.
• Ensure that the power supply line is suitably arranged and protected.
• Ensure that routings of cables through walls or bulkheads are protected
and insulated by appropriate bushing, grommets or cable conduits.
• Secure all cables to prevent any contact with moving parts.
EN
Technical description
15