9.2

venturi adjustment

This appliance has an air shutter that has been factory set open according to
the chart below:
Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carbonization. Opening the air shutter will cause
a more blue flame, but can cause flame lifting from the burner ports. The flame
may not appear yellow immediately; allow 15 to 30 minutes for the final flame
colour to be established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER.
note:
It is important that the orifice is securely inserted into the venturi.
GDS28-1
NG
3/8" (9.5mm)
P
5/16" (7.9mm)
9.3

flame characteristics

It's important to periodically perform a visual check of
the pilot and burner flames. Compare them to the
illustration provided. If any flames appear abnormal,
call a service person.
VENTURI
BURNER
PSE THERMOCOUPLE
ORIFICE
3/8" - 1/2"
(9.5mm - 12.7mm)
Flame must envelop
upper
3/8" to 1/2"
(12.7mm - 9.5mm) of
thermocouple
SIT ELECTRONIC IGNITION
3/8" - 1/2"
ADD IMAGE
(9.5mm - 12.7mm)
HERE
Flame must envelop
upper
3/8" to 1/2"
(12.7mm - 9.5mm) of
Flame sensor
36.1
SIT MILLIVOLT
3/8" - 1/2"
(9.5mm - 12.7mm)
Flame must envelop
upper
3/8" to 1/2"
(12.7mm - 9.5mm) of
thermocouple &
thermopile
PSE LONG SENSOR
3/8" - 1/2"
(9.5mm - 12.7mm)
Flame must envelop
upper
3/8" to 1/2"
(12.7mm - 9.5mm) of
thermocouple
AIR
SHUTTER
OPENING
33.1
W415-4005 / A / 07.22.21
EN
(9
La flam
la therm
(9.5
La
la
(
La flam
la therm
(9.5
37

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Haliburton gs28-1neaHaliburton gds28-1peaHaliburton gs28-1pea

Table des Matières