e. A wire has become disconnected inside the unit during
shipping. Make sure the gas is OFF and the switch is in the
OFF position. The front cover is held by four screws, two top,
two bottom. The knobs pull off. All the wiring is done with
push together plastic connectors. They are all visible without
further dismantling of the unit. It should be obvious when a
wire has become disconnected.
NOTE: Before attempting to remove the cover, call
technical support found on page 1
f. It is possible that some debris or epoxy might have entered
the water regulator. Check to see if the filter screen on the
water inlet is clear of debris. You can also reverse the
hookup by taking your water source and hooking it up to the
water outlet side and back flushing the system.
Propane gas cylinders sometimes are contaminated with air,
especially new tanks upon their first filling. Cycle the unit on and
off by using the shower head switch several times (5) to purge the
air from the gas
Should a unit fail to light or stay lit after 10 cycles, Call
technical support found on page 1
Unit starts and then shuts off:
a. The unit requires a minimum of about 2 liters per minute and a
minimum of about 20 PSI*/1.38 bar. Note, water pressure is at
the lower end of operating parameters. You will need a sustained
water pressure of approximately 40-60 PSI / 2.7-4.1 bar for
adequate use if you are using a 12/18/120/240 volt pump. See
adjustment in previous section.
b. High wind
c. Out of, or low on gas. Propane gas cylinders sometimes are
contaminated with air, especially new tanks upon their first filling.