8. Turn the spray nozzle to the "on" position, turn your
water source on and adjust to the desired water
pattern on the shower head
9. There will be a series of audible clicks and the burner
will ignite. (Should the burner not ignite after 5
seconds, shut off and go to the "Troubleshooting"
section.)
10. After use, open the drain valve (ribbed cylindrical
stem next to the water input valve) to ensure draining
of water
11. Turn off your gas supply
WARNING: If the outside temperature is around or below
freezing (32 degrees F, 0 degrees C), ensure that the
drain valve is opened and water drained from the unit
after each use to avoid internal damage to the water
regulator. You will also need to unhook the outgoing
water line to ensure that any water in the heat exchanger
is drained. Failure to properly drain your unit will cause
water damage which may or may not be reparable.
Please check the warranty information found on our
website
at
information on freezing issues.
Technical Data
Country of destination
Appliance categories
Type of gas
Supply pressure(mbar)
Min gas pressure (mbar)
Max gas pressure (mbar)
Supply pressure(mbar)
Injector Size (mm)
Applicable water pressure (mPa)
Heat Input(Hs)
www.eccotemp.com/freeze
BE, FR, GB, GR, IE, IT,
PT, ES, CH
I 3+
G30/G31
28-30/37
20
35
28-30/37
0.67
for
CY, CZ, DK, EE, FI, LT, MT,
NL, NO, SK, SI, SE, HU, BG,
LV, LU, RO
I 3 B/P
G30
30
20
35
30
0.67
0.025-0.1
10 (Kw)
more
DE, AT, CH,
SK
I 3 B/P
G30
50
42
57
50
0.6
9