The temperature of the outgoing water is dependent on the
temperature of the incoming water balanced with the amount of
heat applied. Use extreme caution in setting the outlet water
temperature.
1. With the water regulator set to high, and the gas
regulator set to low, feel the outgoing water. This is
the lowest setting available.
2. To initially raise the outgoing temperature, slowly
turn the gas valve towards maximum. Adjust slowly
and check the temperature often. There will be a
slight delay between increasing the gas supply and
the increase in water temperature.
3. Should the outlet water temperature need to be
higher, slowly reduce the water flow regulator until
desired temperature is reached.
THE UNIT IS CAPABLE OF PRODUCING
SCALDING TEMPERATURES!
4. If you wish to use water with out it being heated, turn
the ON/OFF switch at the bottom of the unit to "OFF"
("0"). This will disconnect the igniters and gas flow.